{"product_id":"traulsen-tbc1hr-cor01","title":"Traulsen TBC1HR-COR01 Roll-Thru Blast Chiller, Remote","description":"\u003cp\u003eThe Traulsen TBC1HR-COR01 is a roll-thru blast chiller designed to chill product loaded on one compatible roll-in rack. Its touchscreen supports automatic or manual operation, with four chill settings and three removable food probes for tracking product-temperature cycles. An on-board printer and 90-day cycle-data memory support documented batch workflows.\u003c\/p\u003e\u003cp\u003eThis is a remote-condensing configuration: the cabinet’s maintenance refrigeration system is not the complete blast-chill refrigeration package. Plan for an adequately sized remote R-407A condensing unit and qualified refrigeration installation. The cabinet accommodates one rack, but the rack is an optional accessory rather than standard equipment.\u003c\/p\u003e\u003ch2\u003eApplications and Workflow\u003c\/h2\u003e\u003cp\u003eSuitable for commissaries, production kitchens, bakeries, healthcare foodservice, and other operations that need to move batches through a blast-chill workflow on a roll-in rack. This model requires a separately provided remote condensing unit for blast-chill operation; it is not a plug-in, fully self-contained blast chiller. Confirm rack dimensions and refrigeration scope before purchase.\u003c\/p\u003e\u003ch2\u003eFeatures and Practical Benefits\u003c\/h2\u003e\u003ch3\u003eRoll-thru rack workflow\u003c\/h3\u003e\u003cp\u003eThe cabinet is configured for one roll-in rack, allowing a loaded rack to be moved into the chiller instead of transferring pans individually.\u003c\/p\u003e\u003ch3\u003eFlexible cycle control\u003c\/h3\u003e\u003cp\u003eAutomatic and manual touchscreen operation lets staff run preset-style cycles or adjust target temperatures and cycle times for the product being chilled.\u003c\/p\u003e\u003ch3\u003eFour chill settings\u003c\/h3\u003e\u003cp\u003eBlast Chill, Speed, Energy Saving, and Delicate settings provide distinct operating selections for varying production workflows.\u003c\/p\u003e\u003ch3\u003eCycle documentation tools\u003c\/h3\u003e\u003cp\u003eThree removable probes monitor product temperature, while the on-board printer and 90-day data memory support cycle recordkeeping.\u003c\/p\u003e\u003ch3\u003eService-oriented cabinet design\u003c\/h3\u003e\u003cp\u003eStainless steel interior and exterior construction and long-life door gaskets are intended for commercial production environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer model\u003c\/th\u003e\n\u003ctd\u003eTBC1HR-COR01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eRoll-thru blast chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRack capacity\u003c\/th\u003e\n\u003ctd\u003e1 roll-in rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum rack dimensions\u003c\/th\u003e\n\u003ctd\u003e27 in. W x 29 in. D x 72 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct capacity\u003c\/th\u003e\n\u003ctd\u003e300 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan capacity\u003c\/th\u003e\n\u003ctd\u003e26 pans, 12 in. x 20 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e48 1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall depth, roll-thru model\u003c\/th\u003e\n\u003ctd\u003e41 1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e90 3\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClear door opening\u003c\/th\u003e\n\u003ctd\u003e27 1\/4 in. W x 74 1\/8 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical service\u003c\/th\u003e\n\u003ctd\u003e115\/60\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFull-load amps\u003c\/th\u003e\n\u003ctd\u003e16.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired circuit\u003c\/th\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote condensing requirement\u003c\/th\u003e\n\u003ctd\u003eAdequately sized remote condensing unit required for blast-chill operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended blast-chill capacity\u003c\/th\u003e\n\u003ctd\u003e18,700 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote refrigerant\u003c\/th\u003e\n\u003ctd\u003eR-407A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction-line connection\u003c\/th\u003e\n\u003ctd\u003e7\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLiquid-line connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl modes\u003c\/th\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChill settings\u003c\/th\u003e\n\u003ctd\u003eBlast Chill, Speed, Energy Saving, and Delicate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFood probes\u003c\/th\u003e\n\u003ctd\u003e3 removable probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCycle-data memory\u003c\/th\u003e\n\u003ctd\u003e90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation and Purchasing Considerations\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAllow a footprint of 48 1\/2 in. W x 41 1\/4 in. D x 90 3\/8 in. H for the roll-thru cabinet, then verify aisle and door-swing clearance at the installed location.\u003c\/li\u003e\n\u003cli\u003eProvide 115\/60\/1 electrical service with a 20 A required circuit for the maintenance refrigeration system; the specification lists no plug.\u003c\/li\u003e\n\u003cli\u003eThis model requires connection to an adequately sized remote condensing unit for blast-chill operation. The manufacturer specifies R-407A for the remote condensing provision.\u003c\/li\u003e\n\u003cli\u003eCoordinate refrigerant piping with the refrigeration installer: the listed suction-line connection is 7\/8 in. and liquid-line connection is 1\/2 in.\u003c\/li\u003e\n\u003cli\u003eProvide a floor drain or select the optional condensate evaporator for condensate removal.\u003c\/li\u003e\n\u003cli\u003eConfirm the rack separately. The cabinet accepts one roll-in rack up to 27 in. W x 29 in. D x 72 in. H, with wheels inboard of the frame.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoosing This Configuration\u003c\/h2\u003e\u003cp\u003eTBC1HR-COR01 is the roll-thru version of the TBC-series cabinet, rather than a roll-in-only configuration.\u003c\/p\u003e\u003cp\u003eThe cabinet accommodates one rack; a roll-in rack is not supplied as standard equipment.\u003c\/p\u003e\u003cp\u003eA label-printer-equipped version is identified separately by an “-LP” suffix. This model includes the on-board cycle data printer described in the standard features, but no separate label printer is specified.\u003c\/p\u003e\u003cp\u003eDo not confuse the maintenance refrigeration system with the remote blast-chill condensing equipment required for operation.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes the TBC1HR-COR01 include a remote condensing unit?\u003c\/h3\u003e\u003cp\u003eNo. Blast-chill operation requires connection to an adequately sized remote condensing unit. The manufacturer identifies air-cooled and water-cooled remote condensing units as options.\u003c\/p\u003e\u003ch3\u003eIs a roll-in rack included with this blast chiller?\u003c\/h3\u003e\u003cp\u003eNo rack is supplied as standard. This cabinet accommodates one optional roll-in rack with maximum dimensions of 27 in. wide, 29 in. deep, and 72 in. high.\u003c\/p\u003e\u003ch3\u003eWhat electrical service does the cabinet require?\u003c\/h3\u003e\u003cp\u003eThe maintenance refrigeration system is specified for 115\/60\/1 power, 16.0 full-load amps, and a 20 A required circuit. No plug is listed.\u003c\/p\u003e\u003ch3\u003eHow much product can it handle?\u003c\/h3\u003e\u003cp\u003eThe TBC1HR family specification lists a 300 lb product capacity and capacity for up to 26 full-size 12 in. x 20 in. pans. Actual loading depends on the separately selected rack and product arrangement.\u003c\/p\u003e","brand":"Traulsen","offers":[{"title":"Default Title","offer_id":67647038947558,"sku":"TRA-TBC1HR-COR01","price":102747.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/2369\/5846\/files\/tra-tbc1hr-cor01-tra-tbc1hr-cor01.jpg?v=1791399787","url":"https:\/\/www.atlanticse.com\/products\/traulsen-tbc1hr-cor01","provider":"Atlantic Restaurant \u0026 Supermarket Equipment","version":"1.0","type":"link"}