{"product_id":"traulsen-tbc2h-7","title":"Traulsen TBC2H-7 Double-Depth Roll-In Blast Chiller, Remote","description":"\u003cp\u003eThe Traulsen TBC2H-7 is a double-depth, left-hinged roll-in blast chiller designed to chill product loaded on up to two mobile racks. Its touch-screen controller supports automatic or manually adjusted cycles, with selectable target temperatures or cycle times for organized batch production.\u003c\/p\u003e\u003cp\u003eThis model requires two remote R-407A condensing units for blast-chill operation; those condensing units are not supplied with the cabinet. It provides a self-contained maintenance refrigeration system after the chill cycle, while the remote equipment handles the high-capacity blast-chill duty. Roll-in racks are optional and must be selected separately.\u003c\/p\u003e\u003ch2\u003eApplications and Workflow\u003c\/h2\u003e\u003cp\u003eSuitable for commissaries, healthcare kitchens, large catering operations, banquet production, and other commercial kitchens that need to move high-volume batches into a blast chiller on mobile racks. The cabinet accommodates two racks loaded front to back. It is not a plug-in, all-in-one blast chiller: the installation must include two properly sized remote condensing units and associated refrigeration work.\u003c\/p\u003e\u003ch2\u003eFeatures and Practical Benefits\u003c\/h2\u003e\u003ch3\u003eTwo-rack roll-in capacity\u003c\/h3\u003e\u003cp\u003eThe double-depth cabinet accommodates two roll-in racks, helping teams transfer larger production batches without unloading pans into fixed cabinet shelving.\u003c\/p\u003e\u003ch3\u003eFlexible cycle control\u003c\/h3\u003e\u003cp\u003eThe touch-screen control offers automatic and manual operation, adjustable target temperatures or cycle times, and Blast Chill, Speed, Energy Saving, and Delicate settings.\u003c\/p\u003e\u003ch3\u003eBatch documentation tools\u003c\/h3\u003e\u003cp\u003eAn onboard cycle-data printer and USB port support cycle record handling, while the controller stores cycle data for up to 90 days.\u003c\/p\u003e\u003ch3\u003eRemote blast-chill design\u003c\/h3\u003e\u003cp\u003eTwo remote R-407A condensing units are required for blast-chill operation, allowing the refrigeration installation to be planned around the facility rather than relying on an onboard blast-chill condenser.\u003c\/p\u003e\u003ch3\u003eDurable, service-oriented cabinet\u003c\/h3\u003e\u003cp\u003eThe cabinet has stainless steel inside and out, a cylinder lock, self-closing cam-lift hinges with a 120° stay-open position, and front-facing condenser coils for the maintenance system.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer model\u003c\/th\u003e\n\u003ctd\u003eTBC2H-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eDouble-depth roll-in blast chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDoor hinging\u003c\/th\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e48 1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall depth\u003c\/th\u003e\n\u003ctd\u003e71 5\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e90 3\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet capacity\u003c\/th\u003e\n\u003ctd\u003e72.3 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRack capacity\u003c\/th\u003e\n\u003ctd\u003e2 roll-in racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum rack size\u003c\/th\u003e\n\u003ctd\u003e27 in. W x 29 in. D x 72 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct capacity\u003c\/th\u003e\n\u003ctd\u003e600 lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical service\u003c\/th\u003e\n\u003ctd\u003e208-230\/115V, 60 Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical feeds\u003c\/th\u003e\n\u003ctd\u003eTwo 4-wire feeds with ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFull-load amps\u003c\/th\u003e\n\u003ctd\u003eTwo 16.0 A loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired circuits\u003c\/th\u003e\n\u003ctd\u003eTwo 20 A circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote refrigeration requirement\u003c\/th\u003e\n\u003ctd\u003eTwo remote R-407A condensing units required for blast chill operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended chill capacity\u003c\/th\u003e\n\u003ctd\u003eTwo 18,700 BTU\/hr requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant line connections\u003c\/th\u003e\n\u003ctd\u003e7\/8 in. suction; 1\/2 in. liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDoor stay-open position\u003c\/th\u003e\n\u003ctd\u003e120°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData memory\u003c\/th\u003e\n\u003ctd\u003e90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation and Purchasing Considerations\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlan a footprint of 48 1\/2 in. W x 71 5\/8 in. D x 90 3\/8 in. H. The cabinet ships in two cartons and requires jobsite assembly.\u003c\/li\u003e\n\u003cli\u003eProvide two 208-230\/115V, 60 Hz, single-phase electrical feeds. Each feed requires four wires with ground, has a 16.0 A full-load rating, and requires a 20 A circuit. No plug is specified.\u003c\/li\u003e\n\u003cli\u003eThis TBC2H-7 has a left-hinged door. Allow room for the door to swing and use its 120° stay-open position during rack loading and cleaning.\u003c\/li\u003e\n\u003cli\u003eArrange refrigeration installation for two remote R-407A condensing units. The manufacturer lists 18,700 BTU\/hr recommended chill capacity and identifies 7\/8 in. suction and 1\/2 in. liquid line connections.\u003c\/li\u003e\n\u003cli\u003eProvide a floor drain for condensate removal, or specify optional condensate evaporators. Confirm remote-condensing-unit placement, piping, electrical work, drainage, and final assembly with qualified installers before delivery.\u003c\/li\u003e\n\u003cli\u003eRoll-in racks are not standard equipment. Confirm rack dimensions and availability separately; the cabinet accepts racks up to 27 in. W x 29 in. D x 72 in. H, with wheels inboard of the frame.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoosing This Configuration\u003c\/h2\u003e\u003cp\u003eTBC2H-7 is the left-hinged roll-in configuration. The TBC2H-8 is the right-hinged roll-in configuration.\u003c\/p\u003e\u003cp\u003eThe TBC2HR configuration is roll-through rather than this model's roll-in arrangement.\u003c\/p\u003e\u003cp\u003eA label printer is an option identified by the “-LP” suffix; it is not established as included with the base TBC2H-7.\u003c\/p\u003e\u003cp\u003eRemote condensing units and roll-in racks are separate items, not included cabinet components.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes the TBC2H-7 include remote condensing units?\u003c\/h3\u003e\u003cp\u003eNo. Blast-chill operation requires two remote R-407A condensing units. They must be planned and installed separately.\u003c\/p\u003e\u003ch3\u003eHow many racks can this blast chiller hold?\u003c\/h3\u003e\u003cp\u003eIt accommodates two roll-in racks loaded front to back. Racks are optional and are not supplied as standard equipment.\u003c\/p\u003e\u003ch3\u003eWhat electrical service does this model need?\u003c\/h3\u003e\u003cp\u003eIt requires two 208-230\/115V, 60 Hz, single-phase feeds. Each feed uses four wires with ground and requires a 20 A circuit; no plug is specified.\u003c\/p\u003e\u003ch3\u003eWhich way does the door hinge?\u003c\/h3\u003e\u003cp\u003eThe TBC2H-7 is the left-hinged roll-in version. Its door has a stay-open feature at 120°.\u003c\/p\u003e","brand":"Traulsen","offers":[{"title":"Default Title","offer_id":67647049302246,"sku":"TRA-TBC2H-7","price":180546.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/2369\/5846\/files\/tra-tbc2h-7-tra-tbc2h-7.jpg?v=1791400046","url":"https:\/\/www.atlanticse.com\/products\/traulsen-tbc2h-7","provider":"Atlantic Restaurant \u0026 Supermarket Equipment","version":"1.0","type":"link"}