{"product_id":"traulsen-tbc2hr-2","title":"Traulsen TBC2HR-2 Double-Depth Roll-Thru Blast Chiller","description":"\u003cp\u003eThe Traulsen TBC2HR-2 is a double-depth, roll-thru blast chiller built to move loaded racks through a high-capacity chilling station. Its touch-screen controller supports automatic or manual cycles, selectable chill settings, product probes, cycle-data storage, USB export, and an onboard printer for documenting cycle activity.\u003c\/p\u003e\u003cp\u003eThis exact TBC2HR-2 configuration accepts two roll-in racks positioned front to back and has a 600 lb estimated product capacity. It is a remote-condensing installation: two appropriately sized remote R-407A condensing units are required for blast-chill operation and are not standard with the cabinet. Roll-in racks are optional rather than supplied with the unit.\u003c\/p\u003e\u003ch2\u003eApplications and Workflow\u003c\/h2\u003e\u003cp\u003eSuitable for commissaries, institutional kitchens, banquet production, and other high-volume operations that need to chill product loaded on mobile racks. The roll-thru arrangement supports a pass-through rack workflow. This model requires remote refrigeration infrastructure and is not a plug-in, self-contained blast chiller package.\u003c\/p\u003e\u003ch2\u003eFeatures and Practical Benefits\u003c\/h2\u003e\u003ch3\u003eTwo-rack roll-thru workflow\u003c\/h3\u003e\u003cp\u003eThe cabinet accommodates two roll-in racks, loaded front to back, helping separate the loading and unloading sides of a rack-based production flow.\u003c\/p\u003e\u003ch3\u003eFlexible cycle control\u003c\/h3\u003e\u003cp\u003eThe water-resistant touch screen offers automatic and manual operation, with adjustable product targets from 40°F to -5°F or time-based cycles.\u003c\/p\u003e\u003ch3\u003eCycle documentation tools\u003c\/h3\u003e\u003cp\u003eFour removable food probes, an onboard cycle-data printer, a USB port, and 90-day cycle-data memory support recorded cycle management.\u003c\/p\u003e\u003ch3\u003eRemote-system planning clarity\u003c\/h3\u003e\u003cp\u003eBlast-chill operation requires two remote R-407A condensing units; account for this refrigeration scope during project planning.\u003c\/p\u003e\u003ch3\u003eDurable service-oriented cabinet\u003c\/h3\u003e\u003cp\u003eStainless steel is used for the interior and exterior, while the maintenance-system condenser coils face forward for access.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer model\u003c\/th\u003e\n\u003ctd\u003eTBC2HR-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eDouble-depth roll-thru blast chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e48.5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall depth, roll-thru model\u003c\/th\u003e\n\u003ctd\u003e75.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e90.38 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClear door opening\u003c\/th\u003e\n\u003ctd\u003e27.75 in. W x 74.125 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRack capacity\u003c\/th\u003e\n\u003ctd\u003e2 roll-in racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum rack dimensions\u003c\/th\u003e\n\u003ctd\u003e27 in. W x 29 in. D x 72 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEstimated pan capacity\u003c\/th\u003e\n\u003ctd\u003eUp to 52 12 in. x 20 in. pans (26 per rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct capacity\u003c\/th\u003e\n\u003ctd\u003e600 lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct target temperature range\u003c\/th\u003e\n\u003ctd\u003e40°F to -5°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChill settings\u003c\/th\u003e\n\u003ctd\u003eBlast Chill, Speed, Energy Saving, Delicate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFood probes\u003c\/th\u003e\n\u003ctd\u003e4 removable probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCycle-data memory\u003c\/th\u003e\n\u003ctd\u003e90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003e208-230\/115 V, 60 Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequired circuits\u003c\/th\u003e\n\u003ctd\u003eTwo 20 A circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeed wires with ground\u003c\/th\u003e\n\u003ctd\u003eTwo 4-wire feeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote condensing requirement\u003c\/th\u003e\n\u003ctd\u003eTwo remote R-407A condensing units required for blast-chill operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended remote refrigeration load\u003c\/th\u003e\n\u003ctd\u003eTwo 18,700 BTU\/hr circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant line connections\u003c\/th\u003e\n\u003ctd\u003e7\/8 in. suction; 1\/2 in. liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJobsite assembly\u003c\/th\u003e\n\u003ctd\u003eShips in two cartons; assembly required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation and Purchasing Considerations\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePlan a footprint of 48.5 in. W x 75.25 in. D x 90.38 in. H for the roll-thru model; confirm aisle space and door travel at both ends before final placement.\u003c\/li\u003e\n\u003cli\u003eThe clear door opening is 27.75 in. W x 74.125 in. H. Rack dimensions must fit the stated maximum of 27 in. W x 29 in. D x 72 in. H, with wheels inboard of the frame.\u003c\/li\u003e\n\u003cli\u003eThe unit ships in two cartons and requires jobsite assembly.\u003c\/li\u003e\n\u003cli\u003eProvide two remote R-407A condensing units sized for blast-chill operation. The manufacturer lists a recommended load of two 18,700 BTU\/hr circuits at the evaporator and 7\/8 in. suction plus 1\/2 in. liquid connections.\u003c\/li\u003e\n\u003cli\u003eElectrical data calls for 208-230\/115 V, 60 Hz, single-phase service with two 20 A required circuits and two 4-wire feeds with ground. No plug is listed; arrange hardwired installation by a qualified installer.\u003c\/li\u003e\n\u003cli\u003eProvide condensate removal through a floor drain or separately selected optional condensate evaporators. The manufacturer lists two automatic electric condensate evaporators as field-installed options.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoosing This Configuration\u003c\/h2\u003e\u003cp\u003eTBC2HR-2 is the roll-thru configuration in the TBC series, not a single-side roll-in configuration.\u003c\/p\u003e\u003cp\u003eThe listed configuration uses front-hinged\/right-hinged roll-thru doors; do not select this unit based on a single-door left- or right-hinge assumption.\u003c\/p\u003e\u003cp\u003eThis model does not include the two remote condensing units required for blast-chill operation.\u003c\/p\u003e\u003cp\u003eRoll-in racks are not supplied as standard equipment. Verify rack dimensions and quantity separately.\u003c\/p\u003e\u003cp\u003eA label-printer version is a distinct configuration identified with an added “-LP” suffix; this TBC2HR-2 listing is not identified as the label-printer version.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eAre roll-in racks included with the TBC2HR-2?\u003c\/h3\u003e\u003cp\u003eNo. The cabinet accommodates two roll-in racks, but the manufacturer states that racks are not supplied as standard equipment. Racks must be selected separately and should not exceed 27 in. W x 29 in. D x 72 in. H with wheels inboard of the frame.\u003c\/p\u003e\u003ch3\u003eDoes this blast chiller include its remote condensing units?\u003c\/h3\u003e\u003cp\u003eNo. Blast-chill operation requires two remote R-407A condensing units. They are listed as accessories\/options rather than standard included equipment.\u003c\/p\u003e\u003ch3\u003eWhat electrical service does this unit require?\u003c\/h3\u003e\u003cp\u003eThe manufacturer lists 208-230\/115 V, 60 Hz, single-phase power, with two 20 A required circuits and two 4-wire feeds with ground. A plug is not listed.\u003c\/p\u003e\u003ch3\u003eCan the TBC2HR-2 be used as a roll-through station?\u003c\/h3\u003e\u003cp\u003eYes. TBC2HR-2 is the roll-thru model and accepts two racks positioned front to back. Plan access at both sides of the cabinet for the intended loading and unloading workflow.\u003c\/p\u003e","brand":"Traulsen","offers":[{"title":"Default Title","offer_id":67647048417510,"sku":"TRA-TBC2HR-2","price":192261.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/2369\/5846\/files\/tra-tbc2hr-2-tra-tbc2hr-2.jpg?v=1791400002","url":"https:\/\/www.atlanticse.com\/products\/traulsen-tbc2hr-2","provider":"Atlantic Restaurant \u0026 Supermarket Equipment","version":"1.0","type":"link"}