Edlund KSUV-18 Helios UV Antimicrobial Knife Cabinet, 12 Knives, 15-Minute Timer, Lockable Door, Stainless, 115V
Description
A wall-mounted UV-C cabinet that cuts E. coli on stored knives by 99% in as little as 5 minutes.
The Edlund KSUV-18 Helios is a stainless steel UV antimicrobial knife cabinet. Two 15-watt UV-C bulbs, mirrored interior walls and a clear, non UV filtering slotted knife holder leave no shadows on the knives, and independent lab tests showed a 99% reduction in E. coli in as little as 5 minutes. A mechanical timer runs up to 15 minutes, and the UV-filtered plexiglass door has a keyed lock and a safety interlock.
Will it fit · Will it hook up
- Outside size
- 19" W x 6" D x 24" H; about 25 lb.
- Mounting
- Wall mount; hardware 12" center to center, at least one set of lag screws into a stud, rated 50 lb. minimum
- Power
- 115V grounded outlet; manual lists 120 VAC; detachable cord with C13 end
- Holds
- 12 knives, or 10 knives and 2 cleavers, plus 1 steel
Plan a grounded outlet within reach of the cord where the cabinet will hang.
UV-C with no shadows
Two 15-watt UV-C bulbs, mirrored interior walls and a clear non UV filtering knife holder expose all knife surfaces.
Lab-tested results
Independent laboratory tests showed a 99% reduction in E. coli bacteria in as little as 5 minutes.
15-minute timer
An easy mechanical belled timer sets up to 15 minutes. LED lights show when the door is closed and a cycle is running.
Locks and protects
The UV-filtered plexiglass door lets staff see the knives, blocks UV rays, has a lockable keyed handle and a safety interlock.
Holds 12 knives
The UVKR-18 rack, an NSF certified component, takes 12 knives, or 10 knives and 2 cleavers, plus one steel.
Delivery and setup
- Inspect the carton for damage before you sign, and note any damage on the delivery receipt.
- Mount it on the wall with hardware 12 inches center to center, at least one set of screws into a stud, using lag screws rated for 50 lb. or more.
- Install the two UV bulbs, plug the cord into a grounded outlet, and use the supplied test strip to check the bulbs: it should turn from yellow to green.
- Knives and steel are not included.
Questions buyers ask
How fast does it work?
Edlund's independent lab tests showed a 99% reduction in E. coli bacteria in as little as 5 minutes. The timer can be set for up to 15 minutes.
What power does it need?
Edlund lists 115 volts on the sell sheet and 120 VAC in the manual. The cabinet must plug into a properly grounded outlet.
How do I know the bulbs still work?
Use the test strip: it changes from yellow to green when the UV-C bulbs work. Replacement bulbs with test strips are part KT391, and extra test strips are KT392.
Is it safe for staff?
The UV-filtered plexiglass door protects operators from UV rays, and a safety interlock door switch stops the UV when the door opens. Never look directly at a UV-C bulb.
How do I clean it?
Take out the rack and wash it in mild soap and water. Wipe the rest of the cabinet with a damp cloth, and avoid splashing water on the bulbs.
Is it for home use?
No. The manual lists it as FCC Class A, not for home use.
What does the warranty cover?
Edlund warrants this product against defects in material and workmanship for one year from the date of purchase. Edlund repairs or replaces defective parts; you return the unit to the factory with freight prepaid.
Specs
| Manufacturer | Edlund |
|---|---|
| Model Number | KSUV-18 |
| Product Code | 39150 |
| Type | UV antimicrobial knife and utensil cabinet |
| Width | 19 Inches |
| Depth | 6 Inches |
| Height | 24 Inches |
| Unit Weight | Approx. 25 lb. |
| Case Weight | 30 lb. |
| Case Cube | 4.3 cu. ft. |
| Voltage | 115 Volts |
| Voltage per Manual | 120 VAC |
| Power Cord | Universal 120VAC cord with C13 end, part C191grounding plug |
| UV Bulbs | 2 x 15-watt UV-C, part BU007replacement kit with test strips KT391 |
| Knife Capacity | 12 knivesor 10 knives and 2 cleaversplus 1 steel |
| Timer | Mechanical belled timer, up to 15 minutes |
| Indicators | LED lights for door closed and cycle in process |
| Door | UV-filtered plexiglasslockable keyed handlesafety interlock |
| Knife Holder | UVKR-18 clear non UV filtering slotted rack, replacement part UV006 |
| Performance | 99% reduction in E. coli in as little as 5 minutes in independent lab tests |
| Mounting | Wall mountablehardware 12" center to center |
| Material | Stainless steel with mirrored interior walls |
| Certifications | NSF Component |
| NSF Scope | NSF component certification applies to the included UVKR-18 knife rack |
| FCC | Class Anot for home use |
| Patent | US Patent 9,339,570 |
| Country of Origin | Assembled in USA |
| Warranty | 1 Year |