Will it fit · Will it plug in

Outside (W × D × H)98‑1/4" × 34‑1/8" × 47‑5/8"
Power110‑120V · 1.06 A · Hardwired Electrical Leads
Temperature40°F Warmest Average Product Temperature
ListedETL Listed, AHRI 1200

Highlights

  • 98-1/4" W x 34-1/8" D x 47-5/8" H
  • 40°F warmest average product temperature
  • Remote DX refrigeration, condensing unit not included
  • Comes with 24 buckets, 8" x 13"
  • Three display levels with an adjustable lower front display
  • 110-120V, 1.06 A, hardwired electrical leads
  • ETL Listed, AHRI 1200; 1-year parts and labor

Specifications

ManufacturerStructural Concepts
Model NumberFLP8
SeriesAllure
Case TypeFLP Straight Open Low Profile Case
Intended ProductFloral products
Width98-1/4"
Depth34-1/8"
Height47-5/8"
Voltage110-120V
Phase1
Hertz60 Hz
Amps1.06 A
Minimum Circuit Amps15 A
Max Overcurrent Protection15 A
Watts104 Watts
Plug TypeHardwired Electrical Leads
GFCI NoteIf GFCI protection is required, use a GFCI breaker, not a GFCI receptacle
Temperature Range40°F Warmest Average Product Temperature
Refrigeration SystemRemote DX; Condensing Unit Not Included
Saturated Suction Temperature26°F
Load, Conventional Rack5,357 BTU/hr
Load, Parallel Rack4,960 BTU/hr
DefrostEvery 4 Hours, 25 Minutes
DrainFloor Drain Required
Buckets24 Buckets, 8" x 13"
ExteriorLaminate (stock colors)
InteriorPowder coated Silversan Black
Rear ExteriorPowder coated Silversan Black
BaseCasters with levelers
End PanelsFull with stainless steel mirror interior
Standard FeaturesAdjustable lower front display, Digital fahrenheit thermometer, Three display levels
Factory OptionsEnd Panels: Cutaway with glass, Refrigeration: Remote DX with thermostat, solenoid & TXV, Sensor: CPC discharge air sensor
Intended EnvironmentType I: Ambient 75°F, 55% Relative Humidity
CertificationsETL Listed, AHRI 1200
StandardsAccordance with AHRI Std 1200, ETL Listed to UL 471, ETL Listed to CAN/CSA 22.2 No. 120
Warranty1-year parts and labor
Warranty OptionSecond-Year Parts and Labor
Clearance4" Minimum to Walls and Ceilings
Placement5 ft. From Exterior Windows, 10 ft. From HVAC Ceiling Vents, 15 ft. From Exterior Doors
LevelingShim During Installation So the Case Is Level and Plumb

Specs

Manufacturer Structural Concepts
Model Number FLP8
Series Allure
Case Type FLP Straight Open Low Profile Case
Intended Product Floral products
Width 98-1/4 Inches
Depth 34-1/8 Inches
Height 47-5/8 Inches
Voltage 110-120 Volts
Phase 1
Hertz 60 Hz
Amps 1.06 Amps
Minimum Circuit Amps 15 Amps
Max Overcurrent Protection 15 Amps
Watts 104 Watts
Plug Type Hardwired Electrical Leads
GFCI Note If GFCI protection is required, use a GFCI breaker, not a GFCI receptacle
Temperature Range 40 Degrees F Warmest Average Product Temperature
Refrigeration System Remote DX; Condensing Unit Not Included
Saturated Suction Temperature 26 Degrees F
Load, Conventional Rack 5,357 BTU/hr
Load, Parallel Rack 4,960 BTU/hr
Defrost Every 4 Hours, 25 Minutes
Drain Floor Drain Required
Buckets 24 Buckets, 8" x 13"
Exterior Laminate (stock colors)
Interior Powder coated Silversan Black
Rear Exterior Powder coated Silversan Black
Base Casters with levelers
End Panels Full with stainless steel mirror interior
Standard Features Adjustable lower front displayDigital fahrenheit thermometerThree display levels
Factory Options End Panels: Cutaway with glassRefrigeration: Remote DX with thermostat, solenoid & TXVSensor: CPC discharge air sensor
Intended Environment Type I: Ambient 75 Degrees F, 55% Relative Humidity
Certifications ETL Listed, AHRI 1200
Standards Accordance with AHRI Std 1200ETL Listed to UL 471ETL Listed to CAN/CSA 22.2 No. 120
Warranty 1-year parts and labor
Warranty Option Second-Year Parts and Labor
Clearance 4" Minimum to Walls and Ceilings
Placement 5 ft. From Exterior Windows10 ft. From HVAC Ceiling Vents15 ft. From Exterior Doors
Leveling Shim During Installation So the Case Is Level and Plumb

Certifications

ETL Listed
AHRI 1200
Call

Description

A refrigerated case that keeps cut flowers fresh at the point of sale.

Structural Concepts FLP8 refrigerated low-profile floral case with buckets of flowers, front angle view

The Structural Concepts FLP8 is a 98-1/4" wide Allure refrigerated floral case. Structural Concepts rates it for a warmest average product temperature of 40°F. It runs on remote DX refrigeration: the condensing unit is not included and a floor drain is required. It measures 98-1/4" W x 34-1/8" D x 47-5/8" H and connects with hardwired electrical leads at 110-120V, 1.06 A.

Will it fit · Will it hook up

Outside size
98-1/4" W x 34-1/8" D x 47-5/8" H
Power
110-120V, 1.06 A, hardwired leads; 15 A max overcurrent protection
Refrigeration
Remote DX; condensing unit not included; floor drain required
Clearance
4" minimum to walls and ceilings

Measure doorways and turns on the delivery path; the smallest outside dimension is the 34-1/8" depth.

Keeps flowers cold

Rated for floral products at 40°F, with a digital Fahrenheit thermometer.

Bucket display

Comes with 24 buckets, 8" x 13".

Three display levels

Three display levels with an adjustable lower front display.

Remote DX

Remote DX refrigeration; the condensing unit is not included.

Delivery and setup

  • Free shipping on this item. See our shipping policy for delivery details.
  • Inspect the crate for damage before you sign, and note any damage on the delivery receipt.
  • Arrives on casters with levelers.
  • Ships with electrical leads for a hardwired connection; plan for an electrician.
  • The remote condensing unit is not included; a refrigeration contractor connects the case to your system, and a floor drain is required.
  • If your inspector requires GFCI protection, use a GFCI breaker, not a GFCI receptacle.
  • Place it at least 5 ft. from exterior windows, 10 ft. from HVAC ceiling vents and 15 ft. from exterior doors.

Questions buyers ask

What power does it need?

It is hardwired with electrical leads at 110-120V, 1-phase, 1.06 A, with 15 A max overcurrent protection.

Will it fit?

The case is 98-1/4" wide, 34-1/8" deep and 47-5/8" high. Measure doorways and turns before delivery.

Is the condensing unit included?

No. This is a remote case, so the condensing unit is not included and a floor drain is required. Structural Concepts lists a 5,357 BTU/hr conventional rack load at a 26°F suction temperature.

What temperature does it hold?

Structural Concepts lists 40°F for floral products. A digital Fahrenheit thermometer is included.

What certifications does it carry?

The Structural Concepts sheet lists built in accordance with AHRI Std 1200, ETL Listed to UL 471, ETL Listed to CAN/CSA 22.2 No. 120.

What is the warranty?

1-year parts and labor. A second-year parts and labor warranty is a factory option.

Do you match lower prices?

Yes. Structural Concepts equipment carries our Best Price Guarantee. Found it lower? Send us the lower price with a quote request or call us, and we will match it.

110-120V HardwiredElectrical leads, no plug.
40°FWarmest average product temperature.
Remote DXCondensing unit not included.
ETL ListedPer the Structural Concepts sheet.

Specs

Manufacturer Structural Concepts
Model Number FLP8
Series Allure
Case Type FLP Straight Open Low Profile Case
Intended Product Floral products
Width 98-1/4 Inches
Depth 34-1/8 Inches
Height 47-5/8 Inches
Voltage 110-120 Volts
Phase 1
Hertz 60 Hz
Amps 1.06 Amps
Minimum Circuit Amps 15 Amps
Max Overcurrent Protection 15 Amps
Watts 104 Watts
Plug Type Hardwired Electrical Leads
GFCI Note If GFCI protection is required, use a GFCI breaker, not a GFCI receptacle
Temperature Range 40 Degrees F Warmest Average Product Temperature
Refrigeration System Remote DX; Condensing Unit Not Included
Saturated Suction Temperature 26 Degrees F
Load, Conventional Rack 5,357 BTU/hr
Load, Parallel Rack 4,960 BTU/hr
Defrost Every 4 Hours, 25 Minutes
Drain Floor Drain Required
Buckets 24 Buckets, 8" x 13"
Exterior Laminate (stock colors)
Interior Powder coated Silversan Black
Rear Exterior Powder coated Silversan Black
Base Casters with levelers
End Panels Full with stainless steel mirror interior
Standard Features Adjustable lower front displayDigital fahrenheit thermometerThree display levels
Factory Options End Panels: Cutaway with glassRefrigeration: Remote DX with thermostat, solenoid & TXVSensor: CPC discharge air sensor
Intended Environment Type I: Ambient 75 Degrees F, 55% Relative Humidity
Certifications ETL Listed, AHRI 1200
Standards Accordance with AHRI Std 1200ETL Listed to UL 471ETL Listed to CAN/CSA 22.2 No. 120
Warranty 1-year parts and labor
Warranty Option Second-Year Parts and Labor
Clearance 4" Minimum to Walls and Ceilings
Placement 5 ft. From Exterior Windows10 ft. From HVAC Ceiling Vents15 ft. From Exterior Doors
Leveling Shim During Installation So the Case Is Level and Plumb

Certifications

ETL Listed
AHRI 1200

Payment & Security

Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What Our Customers Say

Related Products

Recently viewed