Champion 64 PRO-HR 64" Heat Recovery 2-Tank Rack Conveyor Dishwasher, High Temp, 348 Racks/Hr, 21 kW Booster

Champion 64 PRO-HR 64" Heat Recovery 2-Tank Rack Conveyor Dishwasher, High Temp, 348 Racks/Hr, 21 kW Booster

ChampionSKU: CHA-64 PRO-HR

Champion Best Price Guarantee

Found a lower price? We'll match it.

Choose your configuration

$69,138.50Free shipping included

  • Ships in Next business day · free freight delivery
  • Warranty · 1-yr Parts and Labor
  • Best Price Guarantee · found it lower?

Secure checkout

Apple Pay Diners ClubDiscoverGoogle Pay Mastercard Shop Pay Visa

Talk to an equipment specialist

Mon–Sat 8 AM–5 PM ET

Questions about size, power, delivery or a quote for several units?

Call

Will it fit · Will it plug in

Outside (W × D × H)68" × 26‑11/16" × 77‑1/8"
Power208, 240, 480 or 575V
Capacity348 Racks per Hour
Shipping weight865 lb.
ListedcULus, NSF, ENERGY STAR

Measure every doorway on the delivery path before you order.

Highlights

  • 348 racks per hour (NSF) at 0.28 gallons per rack
  • 64" high temp 2-tank conveyor, left-to-right or right-to-left
  • Exhaust air heat recovery with built-in 21 kW booster
  • 68" W x 26-11/16" D x 77-1/8" H; 20" clear opening fits 18" x 26" sheet pans
  • 3-phase 208, 240, 480 or 575V; 15 kW electric tank heat
  • Touchscreen controls, auto fill, auto drain and automated delime
  • cULus, NSF, ENERGY STAR; 1 year parts and labor warranty

Specifications

ManufacturerChampion
Model Number64 PRO-HR
SeriesPRO Series Rack Conveyor
TypeHigh Temperature 2-Tank Rack Conveyor with Heat Recovery
Shipping Weight865 lb.
Width68"
Depth26-11/16"
Height77-1/8"
Machine Length64" Machine, 68" Overall with 2" Table Connections
Crated Length77-1/2"
Load Height34"
Vertical Clearance20" Clear, Accommodates 18" x 26" Sheet Pans
Door Clearance27" in Front
Capacity348 Racks per Hour
Dishes per HourUp to 6,960
Conveyor Speed9.6 ft/min, Pot and Pan Mode 4.6 ft/min, One Rack at a Time
Tank Capacity17 Gal. Wash Tank + 17 Gal. Power Rinse Tank
Rack Complement1 Peg and 1 Flat 20" x 20" Rack
Water per Rack0.28 Gallons
Water per Hour100 Gallons Maximum
Hot Water Connection3/4" NPT, 110°F at 25 psi Flowing with Booster, Initial Fill 34 Gal.
Cold Water Connection1/2" NPT, 55°F Minimum, 30 psi Flowing
Drain Connection1-1/4" NPT, 15 gal/min Maximum Flow
Water HardnessLess than 3.5 Grains per Gallon
TemperatureHigh Temperature
Tank Heat15 kW Electric, Power Rinse 10 kW Electric
BoosterBuilt-In 21 kW, 70°F Rise, Interplumbed and Interwired
Horsepower2 HP wash and 2 HP power rinse pumps; 1/6 HP drive
ExhaustLoad End 200 CFM, Unload End 200 CFM, at 1/4" Static Pressure
Duct Size3-7/8" x 15-7/8" Outside Dimensions
Voltage208, 240, 480 or 575V
Phase3
Hertz60 Hz
ConnectionTwo Point Standard, Field Convertible to Single Point except 208V
Rated Amps, Single Point with 21 kW Booster208V 3-ph: call factory, 240V 3-ph: 131 A, 175 A min. circuit, 480V 3-ph: 66 A, 90 A min. circuit, 575V 3-ph: 53 A, 70 A min. circuit
Rated Amps, Machine Circuit Only208V 3-ph: 90 A, 110 A min. circuit, 240V 3-ph: 80 A, 100 A min. circuit, 480V 3-ph: 40 A, 50 A min. circuit, 575V 3-ph: 31 A, 40 A min. circuit
Rated Amps, Booster Circuit Only208V 3-ph: 59 A, 80 A min. circuit, 240V 3-ph: 51 A, 70 A min. circuit, 480V 3-ph: 26 A, 35 A min. circuit, 575V 3-ph: 22 A, 30 A min. circuit
Steam Tank Heat Version1-1/2" NPT Steam at 10-30 psi, 1" NPT Condensate, Tank 125 lb/hr, Booster 110 lb/hr
Steam Version Rated Amps208V 3-ph: 15 A, 20 A min. circuit, 240V 3-ph: 14 A, 20 A min. circuit, 480V 3-ph: 7 A, 15 A min. circuit, 575V 3-ph: 6 A, 15 A min. circuit
ConstructionAll Stainless Steel Heavy Gauge incl. Base, Legs and Feet, Front and Side Enclosure Panels
ControlsTouchscreen Display, On-Board Diagnostics, Automated Delime, Auto Fill, Auto Drain, Programmable Dwell
Direction of OperationLeft to Right or Right to Left
Champion Options33" Electric Blower Dryer, Direct Link or Direct Link Plus+ Connectivity
Champion AccessoriesTable Limit Switch, Whisker or Button Style, Vent Cowl with 7" Stacks, Flanged Feet, Water Hammer Kit, Drain Water Tempering Kit, Chemical Pump Kit, Water PRV, Kinetico Water Softener, Peg, Flat and Sheet Pan Racks
Champion Tables and Add-OnsSplash Shields, 24" or 30" Cantilever Sideloader, PRO-90B Corner Loader and Unloader, RCT 64 or RCT 84 Roller Table, Rear Enclosure Panels, Lime Shield Booster Delime
CertificationscULus, NSF, ENERGY STAR
Warranty1 Year Parts and Labor

Resources & Documents

Specs

Manufacturer Champion
Model Number 64 PRO-HR
Series PRO Series Rack Conveyor
Type High Temperature 2-Tank Rack Conveyor with Heat Recovery
Shipping Weight 865 lb.
Width 68 Inches
Depth 26-11/16 Inches
Height 77-1/8 Inches
Machine Length 64" Machine68" Overall with 2" Table Connections
Crated Length 77-1/2 Inches
Load Height 34 Inches
Vertical Clearance 20" ClearAccommodates 18" x 26" Sheet Pans
Door Clearance 27 Inches in Front
Capacity 348 Racks per Hour
Dishes per Hour Up to 6,960
Conveyor Speed 9.6 ft/minPot and Pan Mode 4.6 ft/min, One Rack at a Time
Tank Capacity 17 Gal. Wash Tank + 17 Gal. Power Rinse Tank
Rack Complement 1 Peg and 1 Flat 20" x 20" Rack
Water per Rack 0.28 Gallons
Water per Hour 100 Gallons Maximum
Hot Water Connection 3/4" NPT110°F at 25 psi Flowing with BoosterInitial Fill 34 Gal.
Cold Water Connection 1/2" NPT55°F Minimum30 psi Flowing
Drain Connection 1-1/4" NPT15 gal/min Maximum Flow
Water Hardness Less than 3.5 Grains per Gallon
Temperature High Temperature
Tank Heat 15 kW ElectricPower Rinse 10 kW Electric
Booster Built-In 21 kW, 70°F Rise, Interplumbed and Interwired
Horsepower 2 HP wash and 2 HP power rinse pumps; 1/6 HP drive
Exhaust Load End 200 CFMUnload End 200 CFMat 1/4" Static Pressure
Duct Size 3-7/8" x 15-7/8" Outside Dimensions
Voltage 208, 240, 480 or 575 Volts
Phase 3
Hertz 60 Hz
Connection Two Point StandardField Convertible to Single Point except 208V
Rated Amps, Single Point with 21 kW Booster 208V 3-ph: call factory240V 3-ph: 131 A, 175 A min. circuit480V 3-ph: 66 A, 90 A min. circuit575V 3-ph: 53 A, 70 A min. circuit
Rated Amps, Machine Circuit Only 208V 3-ph: 90 A, 110 A min. circuit240V 3-ph: 80 A, 100 A min. circuit480V 3-ph: 40 A, 50 A min. circuit575V 3-ph: 31 A, 40 A min. circuit
Rated Amps, Booster Circuit Only 208V 3-ph: 59 A, 80 A min. circuit240V 3-ph: 51 A, 70 A min. circuit480V 3-ph: 26 A, 35 A min. circuit575V 3-ph: 22 A, 30 A min. circuit
Steam Tank Heat Version 1-1/2" NPT Steam at 10-30 psi1" NPT CondensateTank 125 lb/hrBooster 110 lb/hr
Steam Version Rated Amps 208V 3-ph: 15 A, 20 A min. circuit240V 3-ph: 14 A, 20 A min. circuit480V 3-ph: 7 A, 15 A min. circuit575V 3-ph: 6 A, 15 A min. circuit
Construction All Stainless Steel Heavy Gauge incl. Base, Legs and FeetFront and Side Enclosure Panels
Controls Touchscreen DisplayOn-Board DiagnosticsAutomated DelimeAuto FillAuto DrainProgrammable Dwell
Direction of Operation Left to Right or Right to Left
Champion Options 33" Electric Blower DryerDirect Link or Direct Link Plus+ Connectivity
Champion Accessories Table Limit Switch, Whisker or Button StyleVent Cowl with 7" StacksFlanged FeetWater Hammer KitDrain Water Tempering KitChemical Pump KitWater PRVKinetico Water SoftenerPeg, Flat and Sheet Pan Racks
Champion Tables and Add-Ons Splash Shields24" or 30" Cantilever SideloaderPRO-90B Corner Loader and UnloaderRCT 64 or RCT 84 Roller TableRear Enclosure PanelsLime Shield Booster Delime
Certifications cULus, NSF, ENERGY STAR
Warranty 1 Year Parts and Labor

Certifications

cULus
NSF
ENERGY STAR
Call

Request custom upholstery pricing

Champion 64 PRO-HR 64" Heat Recovery 2-Tank Rack Conveyor Dishwasher, High Temp, 348 Racks/Hr, 21 kW Booster

Description

A 2-tank high-temp rack conveyor that washes 348 racks an hour and reuses its own exhaust heat.

Champion 64 PRO-HR 2-tank rack conveyor dishwasher with heat recovery unit, front angle view

The Champion 64 PRO-HR is a 64" 2-tank high temperature rack conveyor for hotels, hospitals, schools and busy restaurants. Champion rates it at 348 racks per hour (NSF), up to 6,960 dishes per hour, using 0.28 gallons per rack and 100 gallons per hour at most. Exhaust air energy recovery uses the heat leaving the machine to preheat incoming cold water, and the 21 kW booster is built in, so it runs on a 110°F hot water line. It runs on 3-phase power and is built in left-to-right or right-to-left versions.

Will it fit · Will it hook up

Outside size
68" W x 26-11/16" D x 77-1/8" H including the heat recovery unit, per Champion
Machine length
64" machine plus 2" table connections at each end, 68" overall; crated length 77-1/2"
Clearances
34" load height; 20" clear opening for 18" x 26" sheet pans; 27" in front for the doors; 6" minimum from the back to the wall
Hot water
3/4" NPT, 110°F at 25 psi flowing with the booster; initial fill 34 gal.
Cold water
1/2" NPT, 55°F minimum at 30 psi flowing, feeds the heat recovery coil
Drain
1-1/4" NPT; up to 15 gal. per minute
Venting
Load end 200 CFM and unload end 200 CFM at 1/4" static pressure; fabricated duct 3-7/8" x 15-7/8"
Power
3-phase, 60 Hz. With the 21 kW booster on one connection: 208V 3-ph: call factory | 240V 3-ph: 131 A, 175 A min. circuit | 480V 3-ph: 66 A, 90 A min. circuit | 575V 3-ph: 53 A, 70 A min. circuit
Water hardness
Less than 3.5 grains per gallon

Measure doorways and turns on the delivery path: the narrowest side is the 26-11/16" depth, and the crate is about 77-1/2" long.

348 racks per hour

NSF-rated at 348 racks per hour with a 9.6 ft/min conveyor. Pot and pan mode slows it to 4.6 ft/min, one rack at a time.

0.28 gallons per rack

Water use is 0.28 gallons per rack and 100 gallons per hour at most. The energy sentinel shuts the pumps off when the machine sits idle.

Exhaust heat recovery

A heat recovery coil uses the heat in the exhaust air to preheat the incoming cold water, fed through its own 1/2" cold water line.

Touchscreen and diagnostics

The touchscreen shows condition alerts and cleaning steps in several languages, with on-board diagnostics and an automated delime function.

Built to clean

Single-piece hood, scrap screen and stainless upper and lower wash arm manifolds. Insulated doors open a full 180°.

Delivery and setup

  • Free shipping on this item. See our shipping policy for delivery details.
  • Arrives by freight truck on a pallet. Inspect the crate for damage before you sign, and note any damage on the delivery receipt.
  • Crated weight is 865 lb. Plan a liftgate or forklift and enough people to move it, and check doorway and hall clearances first.
  • Champion says plumbing and electrical connections should be made by qualified personnel under local plumbing, sanitary and safety codes and the National Electrical Code.
  • A water hammer arrestor (ASSE-1010 or equal) must be supplied by others in the water line. Champion does not endorse tankless water heaters or PEX lines for this machine.
  • Champion factory authorized start-up is included as a standard feature.

Questions buyers ask

Is it high temp or low temp?

High temperature. It sanitizes with hot water, using its built-in 21 kW booster fed with 110°F water.

Do I need a booster heater?

No separate booster. The 21 kW booster for a 70°F rise is built in, interplumbed and interwired.

Does it need a hood or venting?

Champion's sheet calls for 200 CFM at the load end and 200 CFM at the unload end at 1/4" static pressure, with a 3-7/8" x 15-7/8" fabricated duct. Plan this with your mechanical contractor. Do not let freezing air be drawn into the heat recovery coil when the building vent fan is off.

What electrical service does it need?

3-phase power. With the 21 kW booster on one connection the rated amps are: 208V 3-ph: call factory; 240V 3-ph: 131 A, 175 A min. circuit; 480V 3-ph: 66 A, 90 A min. circuit; 575V 3-ph: 53 A, 70 A min. circuit.

Can I get steam tank heat?

Yes. Champion builds a steam version with a 1-1/2" NPT steam supply at 10-30 psi and a 1" NPT condensate return. It uses 125 lb/hr for the tank and 110 lb/hr for the booster.

Which way does it run?

It is built as left-to-right or right-to-left. Choose the direction that matches your dish tables before you order; the drawings show both.

What warranty does it have?

Champion lists a 1 year parts and labor warranty. Register the machine with Champion after installation.

Do you match lower prices?

Yes. Champion equipment carries our Best Price Guarantee. Found it lower? Send us the lower price with a quote request or call us, and we will match it.

348 Racks/HrNSF-rated capacity.
0.28 Gal/RackEnergy sentinel idle pump shut-off.
Heat RecoveryExhaust heat preheats incoming water.
ENERGY STARCertified per Champion spec sheet.

Specs

Manufacturer Champion
Model Number 64 PRO-HR
Series PRO Series Rack Conveyor
Type High Temperature 2-Tank Rack Conveyor with Heat Recovery
Shipping Weight 865 lb.
Width 68 Inches
Depth 26-11/16 Inches
Height 77-1/8 Inches
Machine Length 64" Machine68" Overall with 2" Table Connections
Crated Length 77-1/2 Inches
Load Height 34 Inches
Vertical Clearance 20" ClearAccommodates 18" x 26" Sheet Pans
Door Clearance 27 Inches in Front
Capacity 348 Racks per Hour
Dishes per Hour Up to 6,960
Conveyor Speed 9.6 ft/minPot and Pan Mode 4.6 ft/min, One Rack at a Time
Tank Capacity 17 Gal. Wash Tank + 17 Gal. Power Rinse Tank
Rack Complement 1 Peg and 1 Flat 20" x 20" Rack
Water per Rack 0.28 Gallons
Water per Hour 100 Gallons Maximum
Hot Water Connection 3/4" NPT110°F at 25 psi Flowing with BoosterInitial Fill 34 Gal.
Cold Water Connection 1/2" NPT55°F Minimum30 psi Flowing
Drain Connection 1-1/4" NPT15 gal/min Maximum Flow
Water Hardness Less than 3.5 Grains per Gallon
Temperature High Temperature
Tank Heat 15 kW ElectricPower Rinse 10 kW Electric
Booster Built-In 21 kW, 70°F Rise, Interplumbed and Interwired
Horsepower 2 HP wash and 2 HP power rinse pumps; 1/6 HP drive
Exhaust Load End 200 CFMUnload End 200 CFMat 1/4" Static Pressure
Duct Size 3-7/8" x 15-7/8" Outside Dimensions
Voltage 208, 240, 480 or 575 Volts
Phase 3
Hertz 60 Hz
Connection Two Point StandardField Convertible to Single Point except 208V
Rated Amps, Single Point with 21 kW Booster 208V 3-ph: call factory240V 3-ph: 131 A, 175 A min. circuit480V 3-ph: 66 A, 90 A min. circuit575V 3-ph: 53 A, 70 A min. circuit
Rated Amps, Machine Circuit Only 208V 3-ph: 90 A, 110 A min. circuit240V 3-ph: 80 A, 100 A min. circuit480V 3-ph: 40 A, 50 A min. circuit575V 3-ph: 31 A, 40 A min. circuit
Rated Amps, Booster Circuit Only 208V 3-ph: 59 A, 80 A min. circuit240V 3-ph: 51 A, 70 A min. circuit480V 3-ph: 26 A, 35 A min. circuit575V 3-ph: 22 A, 30 A min. circuit
Steam Tank Heat Version 1-1/2" NPT Steam at 10-30 psi1" NPT CondensateTank 125 lb/hrBooster 110 lb/hr
Steam Version Rated Amps 208V 3-ph: 15 A, 20 A min. circuit240V 3-ph: 14 A, 20 A min. circuit480V 3-ph: 7 A, 15 A min. circuit575V 3-ph: 6 A, 15 A min. circuit
Construction All Stainless Steel Heavy Gauge incl. Base, Legs and FeetFront and Side Enclosure Panels
Controls Touchscreen DisplayOn-Board DiagnosticsAutomated DelimeAuto FillAuto DrainProgrammable Dwell
Direction of Operation Left to Right or Right to Left
Champion Options 33" Electric Blower DryerDirect Link or Direct Link Plus+ Connectivity
Champion Accessories Table Limit Switch, Whisker or Button StyleVent Cowl with 7" StacksFlanged FeetWater Hammer KitDrain Water Tempering KitChemical Pump KitWater PRVKinetico Water SoftenerPeg, Flat and Sheet Pan Racks
Champion Tables and Add-Ons Splash Shields24" or 30" Cantilever SideloaderPRO-90B Corner Loader and UnloaderRCT 64 or RCT 84 Roller TableRear Enclosure PanelsLime Shield Booster Delime
Certifications cULus, NSF, ENERGY STAR
Warranty 1 Year Parts and Labor

Certifications

cULus
NSF
ENERGY STAR

Payment & Security

Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

What Our Customers Say

Related Products

Recently viewed