Duke HCF-5 HotColdFreeze 5-Well Hot, Cold and Freeze Drop-In Unit, Touch Screen per Well, 120V or 120/208-240V
Description
5 food wells that each switch between hot, cold and frozen holding, so one counter serves every daypart.
The Duke HCF-5 HotColdFreeze is a 5-well holding unit with flush mount pans in a polished stainless steel top. Every well has its own touch screen and runs in 3 wet heat, 3 dry heat, 3 refrigerated settings or a freeze setting, with no cool-down needed to switch from hot to cold or freeze. Wells take 12" x 20" pans 2-1/2", 4" or 6" deep, each well has a drain, and the R448A compressor slides out for service in the counter.
Will it fit · Will it hook up
- Outside size
- 80-3/16" long x 25-1/2" front to back x 25-15/16" high
- Counter cutout
- 79" x 24" (length x width)
- Power
- Pick in the dropdown: 120V 28 A, NEMA 5-50P; or 120/208V or 120/240V 17.2 A, NEMA L14-30P. 6 ft. cord and plug
- Drain
- 3/4" drain connection at each well, to local code
- Air flow
- Enclosed body: intake min. 16" x 16" in front of the condenser, exhaust min. 20" x 20", 4" side clearance to the refrigeration cage
Controls ship on a bracket and are mounted in the front of your counter body, in well order; see the Duke control cutout.
Four modes per well
Each well runs wet heat WH1-WH3, dry heat DH1-DH3, cold C1-C3 or freeze F, set on its own touch screen.
Switch without waiting
Duke says no cool-down period is needed to switch a well from hot to cold or freeze; wells reach set point in 30 to 60 minutes.
Deep pan choice
Each well takes a standard 12" x 20" pan 2-1/2", 4" or 6" deep, flush with the top.
Service in place
The R448A compressor slides out 15.375" for service, so the unit can be serviced in the counter.
Drain at every well
A drain at each well makes it easy to empty water after wet heat service.
Delivery and setup
- Inspect the crate for damage before you sign, and note any damage on the delivery receipt.
- Duke lists 340 lb. and 45.0 cu. ft. crated, freight class 100, shipped F.O.B. Sedalia, Missouri.
- Choose the voltage in the dropdown; the plug type depends on it. Plug into a dedicated circuit sized for the data plate.
- Connect each 3/4" drain to local code, level the unit and mount the controls in the counter front in the order they shipped.
Questions buyers ask
What can each well do?
Each well has its own control with 3 wet heat, 3 dry heat, 3 refrigerated settings and 1 freeze setting.
Do I need water?
Only for wet heat, which needs at least 1" of water. Dry heat, cold and freeze run dry. Add water only after the well has cooled to room temperature.
Which voltage should I order?
Duke builds it for 120V (28 A, NEMA 5-50P) or 120/208V and 120/240V (17.2 A, NEMA L14-30P). Pick the one that matches your outlet in the dropdown.
What pans fit?
Standard 12" x 20" steam table pans, 2-1/2", 4" or 6" deep, one per well.
Is the compressor covered?
The Duke spec sheet lists a 5 year compressor replacement.
What certifications does it have?
The Duke spec sheet shows the cULus mark and the UL EPH Classified mark to ANSI/NSF 169, and it complies with part 15 of the FCC rules.
Specs
| Manufacturer | Duke |
|---|---|
| Model Number | HCF-5 |
| Series | Duke HotColdFreeze |
| Type | Hot, Cold and Freeze Food Holding Unit, 5 Well |
| Shipping Weight | 340 lb. |
| Crated Cube | 45.0 cu. ft. |
| Freight Class | 100 |
| Width | 80-3/16 Inches |
| Depth | 25-1/2 Inches |
| Height | 25-15/16 Inches |
| Counter Cutout | 79" L x 24" W |
| Liner Width | 23.82" |
| Capacity | 5 Wells, 12" x 20" Pans |
| Pan Depths | 2-1/2", 4" and 6" Deep |
| Voltage | 120 or 120/208 or 120/240 Volts |
| Hertz | 60 |
| Phase | 1 |
| Electrical Options | 120V: 3360 W, 28 A, NEMA 5-50P120/208V: 2064 W, 17.2 A, NEMA L14-30P120/240V: 2064 W, 17.2 A, NEMA L14-30P |
| Cord | 6 Foot Cord and Plug |
| Refrigeration System | System 1: 1/3 HP, R448A, 19.5 oz.System 2: 1/2 HP, R448A, 30.0 oz. |
| Compressor | Slides Out 15.375" for Service5 Year Compressor Replacement |
| Top | Stainless Steel, Formed, Welded and PolishedTop Mount with Flush Mount PansSealing Gasket |
| Drain | 3/4" Drain at Each Well |
| Control Type | Touch Screen, 1 per Well3 Wet Heat, 3 Dry Heat, 3 Refrigerated, 1 Freeze |
| Control Mounting | Mounts in Cabinet Body10" Cable Installed, 6 Foot Cord Supplied if NeededBuilt-In Wi-Fi Modem for Future Activation |
| Factory Options | No Drain, Dry Heat Only with Removable Non-Stick Liner |
| Certifications | cULus, UL EPH Classified ANSI/NSF 169, FCC Part 15 |
Certifications
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What Our Customers Say