Hatco HWBI-6MA Drop-In Modular Heated Well, 6 Full-Size Wells, Insulated, Manifold Drain, Auto-Fill, 208/240V
Description
Six full-size hot wells in one drop-in unit, each with its own thermostat, for a steam table line that installs as one piece.
The Hatco HWBI-6MA groups six insulated full-size (12" x 20") heated wells into one top-mount drop-in unit that measures 85.5" W x 23.63" D. Each well has its own thermostatic control, and one lighted On/Off switch keeps the settings when you power down. The wells drain through a 1" NPT copper manifold; the exit is set on the side or bottom and to the left or right in the field. An auto-fill system tops up water without staff checking it. It runs on 208V or 240V, single phase or optional three phase.
Will it fit · Will it hook up
- Outside size
- 85.5" W x 23.63" D x 9.56" H
- Countertop cutout
- 84.125" to 84.375" W x 22.25" to 22.50" D (EZ locking tabs)
- Power
- 7215 W; 208V 1-ph 34.7 A, 240V 1-ph 30.1 A, 208V 3-ph 20.1 A, 240V 3-ph 17.4 A. Hard wired; an optional factory cord with a NEMA 6-50P plug is available for single phase with a single control box
- Controls
- Single control box standard on a 6 ft flexible conduit; split control boxes optional (US only)
- Drain
- 1" NPT copper manifold drain, side or bottom exit, field selectable left or right
- Water
- 1/4" NPT connection, 25 to 100 psi, 60 to 110°F
- Clearance
- At least 3-1/2" from the bottom of the unit to any combustible surface
Hatco makes these units to order: specify voltage, phase, control boxes and agency listing when you order.
Independent well controls
Each of the six wells has its own thermostat and temperature dial, so you can hold different foods at different settings.
Insulated top-mount wells
Insulated well cavities and stainless steel construction with solid brazed drain fitting joints. EZ locking hardware speeds installation.
Takes standard pans
Each full-size well takes full-size, half-size or third-size pans; adapters for 4- or 7-quart round pans and pan support bars are sold separately.
Manifold drain
All six wells empty through one 1" NPT copper manifold drain with a side or bottom exit, field selectable left or right.
Auto-fill
Auto-fill sits on the left control and fills the left-hand well. Hatco notes that to fill all wells, the installer must connect the drains with an external manifold.
Easy service
Separate well assemblies give independent access to each well, and elements or thermostats change quickly.
Delivery and setup
- Inspect the carton for damage before you sign, and note any damage on the delivery receipt. Approximate shipping weight is 195 lb.
- A qualified electrician must install the unit to local electrical codes. Installation by unqualified personnel voids the Hatco warranty.
- Install with a ribbon putty gasket between the unit and the countertop, per the Hatco manual; a factory-installed gasket is an option at order.
- Let the well cool to room temperature before you switch between wet and dry operation, and never let it run dry while set up for wet operation.
- Auto-fill: bring a potable water line to the 1/4" NPT connection (25 to 100 psi, 60 to 110°F); incoming water pipes must be FDA compliant.
- Drain sealants must be rated for 500°F or higher.
Questions buyers ask
What size cutout do I need?
Cut the countertop 84.125" to 84.375" wide and 22.25" to 22.50" deep for EZ locking tabs. The unit itself is 85.5" W x 23.63" D x 9.56" H. Leave at least 3-1/2" below the unit to any combustible surface.
What electrical service does it need?
Order 208V or 240V, single phase, or three-phase wiring at no charge. It draws 34.7 A at 208V single phase, 30.1 A at 240V single phase, 20.1 A at 208V three phase and 17.4 A at 240V three phase. With optional split control boxes the unit has more than one circuit connection, and each needs its own breaker.
Is a cord and plug included?
No. It is hard wired as standard. Hatco offers a factory cord with a NEMA 6-50P plug for single-phase units with a single control box, at time of order.
Can I use it wet or dry?
Yes. Hatco designs these wells for wet or dry use. Let the unit cool before you switch modes, and do not let it run dry when set up for wet operation.
How does the auto-fill work?
Auto-fill sits on the left control and fills the left-hand well. Hatco notes that to fill all wells, the installer must connect the drains with an external manifold. It needs a 1/4" NPT water connection at 25 to 100 psi and 60 to 110°F.
What warranty does it have?
Hatco's limited warranty covers the metal-sheathed heated well element for 1 year parts and labor plus 1 more year parts only. Other parts carry Hatco's standard 18-month limited warranty. Register the unit with Hatco within 90 days of factory shipment to qualify for added coverage.
Specs
| Manufacturer | Hatco |
|---|---|
| Model Number | HWBI-6MA |
| Series | Drop-In Modular/Ganged Heated Wells, Insulated, Top Mount |
| Shipping Weight | 195 lb. |
| Width | 85.5 Inches |
| Depth | 23.63 Inches |
| Height | 9.56 Inches |
| Countertop Cutout | 84.125 to 84.375 Inches W x 22.25 to 22.50 Inches D, EZ Locking Tabs |
| Capacity | 6 Full-Size 12 x 20 Inch Pans |
| Number of Wells | 6 |
| Voltage | 208 or 240 Volts |
| Phase | Single Phase StandardThree Phase Optional at No Charge |
| Wattage | 7215 Watts |
| Amps | 208V 1-Ph: 34.7 A240V 1-Ph: 30.1 A208V 3-Ph: 20.1 A240V 3-Ph: 17.4 A |
| Plug Type | Hard WiredOptional Cord with NEMA 6-50P, Single Phase and Single Control Box Only |
| Control Type | Thermostatic Control per WellLighted On/Off Rocker Switch |
| Control Box | Single Control Box StandardSplit Control Boxes Optional, Not Available in Canada |
| Conduit | 6 ft Flexible Conduit Standard3 ft Optional with Split Control Boxes Only |
| Drain | 1 Inch NPT Copper Manifold Drain, Side or Bottom Exit, Field Selectable Left or Right |
| Auto-Fill | Left Control, Fills Left-Hand Well |
| Water Connection | 1/4 Inch NPT |
| Water Supply | 25 to 100 psi60 to 110°F |
| Construction | Stainless Steel WellsStainless and Aluminized Steel HousingInsulated Well Cavities |
| Heating Element | Metal Sheathed |
| Mounting | Top Mount, Drop-InEZ Locking Hardware |
| Factory Options | Three-Phase WiringCopper Manifold Drain with Side or Bottom ExitCord for Single Phase27 Inch Deep Bezel to Match Hatco CWB WellsFactory-Installed GasketAt Time of Purchase Only |
| Accessories | 1- and 2-Pan Heated Well CoversFood PansRound Pan Adapters12 or 20 Inch Pan Support BarsExternal Drain Manifold with ValvesBall and Gate ValvesRemote Drain Handle |
| Certifications | cULus, UL EPH |
| Agency Listing | UL and C-UL ListedUL EPH Sanitation Listing per ANSI/NSF 4Specify Agency at Order |
| Country of Origin | Made in USA |
| Warranty | Heated Well Element 1 Year Parts and Labor Plus 1 Year Parts OnlyOther Parts 18 Months |
Certifications
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
What Our Customers Say